THE CATALOG OF EQUIPMENT” TYCO ELECTRONICS RAYCHEM” Articles for the cable with the copper veins
System of connection for the distributive user network (of type VX) Modular system of connection VX Five-pole module of connection (VX- MD) Insertable modules (VX- PM) Modular user block of connection (VX-DR) End block with the possibility of guaranteeing the electrical protection (VX-BL) User distributive boxings The terminal block of connection (VX- SB, VX-DW) Pay of the end fitting (VX-IB) User distributive boxings (VX- TB, VX-DB, VX-TBL) User distributive boxings with the stabilized cable (VX-TB- THE XX -028)
|
VX - TB, VX - TBL Distributive boxing with the possibility of the installation the elements of the protectionBoxing is intended for the end fitting of distribution cables and their joint with the pairs of the subscriber lines.
The module of connection VX allows the possibility of the connection between the station cable pair and the distributive pair.
Is possible the connection of 5 polar insertable module for the through connection and the protection.
The removal of change module does not disrupt wire connections, but are made themselves contacts to them accessible for both testing the sides of network.
|
 |
It is recommended for:
- installation before open air, where the environmental conditions are extremely aggressive,
- the connection, where is necessary flexibility for further development or changing the configuration before the plan of a change in the type of protection or filter.
Boxing consists of housing and cover besides which on the tire DIN they are placed modules VX. The construction of the housing of boxing provides the possibility of wall installation. The construction of the cover of boxing provides the possibility of its fixation with the opening before any position, which can be selected on the basis of the existing working space and also for the sake of padding for averting the penetration of moisture on its joint with the base of housing. The base of housing is equipped for the sake of stuffing boxes for the introduction beside the boxing of distributive wires. The triggering of locking mechanism is produced as far as special key or screwdriver, depending on the type of lock. The modules of connection are developed for the installation down the tire on the standard DIN and therefore, they can be established before a number or before two rows.
Boxing can be prepared down the capacity from 5 to 30 pairs, with the step of a change in the capacity, equal to 5 pairs, and it can also provide for the end fitting of control (official) pairs. Small width (2 cm.) guarantees compactness of article. |
Sizes
 |
Information for the order
| Marking |
Quantity of the pairs |
Configuration of the connected module |
Control access |
Number of the order |
| VX-TB-05- P |
5
|
Through connection |
Yes |
|
| VX- TB -05-PG04 |
5
|
With the protection on the stress (gas-discharge arrester down 230) |
Yes |
|
| VX- TB -05-XG04 |
5
|
With the protection on the stress (gas-discharge arrester down 230) |
No |
|
| VX- TB -05-PG03 |
5
|
With the protection on the stress (gas-discharge arrester beyond 260 c) |
Yes |
|
VX- TB -05-XGP01
|
5
|
With the protection on the stress (gas-discharge arrester beyond 230 c) and to current. |
No |
|
| VX-TBL-10- P |
10
|
Through connection |
Yes |
712246 - 000
|
| VX-TBL-10-XG-04 |
10
|
Gas-discharge arrester down 230 [v] |
No |
|
| VX-TBL-10-XGP-01 |
10
|
With the protection on the stress (gas-discharge arrester beyond 230 c) and to current. |
No |
|
| VX-TB-15- P |
15
|
Through connection |
Yes |
|
| VX-TB-20- P |
20
|
Through connection |
Yes |
|
| VX-TB-25- P |
25
|
Through connection |
Yes |
|
| VX-TB-30- P |
30
|
Through connection |
Yes |
|
Technical characteristics
| Characteristics of the contact connection |
| Connector of the distributive wire |
| Range of the section: |
diameter 0,4… 1,2 mm |
| Diameter on the isolation: |
it is maximal 5 mm |
| The current-response characteristics: |
20 A (10 A on each conductor) during not less than 10 min, without the deformation of the module |
Insulation resistance
|
Dry atmosphere:
|
> 10 12[Om] |
| Moist atmosphere: |
> 10 12[Om] |
(standard ASTM Of d618, procedure F)
|
Salt fog:
|
> 10 10[Om] |
(standard ASTM Of b117)
|
| Immersion beside the water: |
>1010[Om] |
| (15 days before 3% solution Of naCI) |
| The contact resistance: |
<10 m |
R of material + R of the contact cross connection + R of the contact connection of the wires |
|
Increase in the contact resistance
|
| After climatic testings: |
< 2,5 m |
| After 50 connections - turning offs: |
<2,5 m |
| Dielectric strength: |
>3 kV of direct current during 1 minute |
Price see before the division “the price list Of tyco”
|
 |