Down the main thing Rambler's Of top100
Catalog of imported communication equipment
Price list the electronic components

on the company
our coordinates
we on the exhibitions
we before the press
our partners
the order of the equipment



the equipment Of tyco
the price list Of tyco
the certificates
[otech]. the equipment
the price list



the equipment Of lucent
the price list Of lucent



the equipment
the price list



the equipment
the price list



the equipment
the price list



the equipment
the price list



the Internet- store
to [skachat] the price list


Search:
Rambler's Of top100

THE CATALOG OF EQUIPMENT” TYCO ELECTRONICS RAYCHEM”
Articles for the cable with the copper veins

Cross-connecting and terminal equipment:
QDF, VX, UCS, [S]5[S]

Cross-connecting equipment of the type UCS

Skirting UCSSkirting UCS uses V-shaped contact with the turn at angle of 45°. The broad spectrum of the articles is produced: skirtings, accessories to them, distributive boxings and cabinets.

The family of articles UCS (Universal Of connection Of system, the universal system of connection) is the reliable, rapid and simple before the application system of the cross-connecting connections of conductors. The basis of the connecting (with the normally closed contacts) skirting UCS-DM of entering the family of articles UCS, are fitted contacts IDC (insulation of displacement of contact, contact connection for the sake of the slotting of isolation). This ensures the rapid and reliable end fitting of conductors without the need for the expenditures of time for the removal of isolation, and also of expenditures of time for winding or soldering. The construction of terminal devices on the basis of fitted contacts IDC makes it possible to produce the end fitting of conductors with different sections of veins - is ensured the connection of single-wire veins by diameter from 0,40 to 0,64 mm (size from 26AWG to 22 AWG across the American notation of the diameters of veins).

Fitted contact IDC ensures also the connection to it of conductors with different forms of isolation - both of the high-density polyethylene and from the polyvinylchloride plastic material of the widely used formulas. Material of fitted contact - bronze with the coating for the sake of silver. Skirting UCS-DM is expected at the point of the connection of 10 pairs and is intended for the application it is when required at present or subsequently to ensure electrical protection, measurements or circuit break. Skirtings UCS- CM are established beyond the distributive stands of cross-connecting equipment ATS and beyond the introductory equipment of user, and also they adapt before the line-cable equipment.

The arrangement of each fitted contact inside the plastic housing of the skirting, which has guide slots, ensures convenience in computation and connection of conductors to the skirting. All places of connection are arranged before tele- insulating housing, thanks to which the frontal side of skirting is electrically “damped”, which prevents the possibility of the short circuits of conductors on the frontal side. In the construction of skirting it is laid the possibility of fulfilling the measurements of chains before both directions, monitoring the characteristics of chains, break of the connection of chains. Is provided the broad spectrum of the versions of electrical protection, and also the broad spectrum of equipment for the skirtings, such as measuring and commutation cords, the framework for the marking labels, including hinged, insert for marking of separate chains and fork for turning off of line.

Technical characteristics

Sizes, mm 123,5 X of 21,36 X 39,42
Insulation resistance 100 G
Common contact resistance < 10 m
The contact resistance < 1 m
Damping is contact < 0,05 dB
[Elektr].[prochnost]/[Impulsnaya] strength 2[kV]/3.6[kV]
Current load 5 kA
Permissible load by pulse current, 8/20 s >10 kA ([nerazmykaemyy])
> 5 kA (opened)
Total capacitance between the adjacent conductors 1 pF
Diameter of vein, single-wire 0,4 - 0,68 mm
Outside diameter of the isolation 0,7 - 1,5 mm
Quantity of the connections 200
Material of the housing 50% polycarbonate + 50% OF ABS, not supporting is the combustion
Material of the contact Alloy of copper, zinc, aluminum. Electrolytic plating for the sake of silver - 6 m
Weakening across the adjacent channel In accordance with the requirements Of [kat].3
300 Hz… of 3400 Hz >110 dB
3,4 kHz… of 10 kHz >102 dB
10 kHz… of 1,2 MHz >63 dB
The operating temperature -20[S] to +80[S]
Storage temperature -40[S] to +90[S]




Present document contains the following divisions:
  1. INTRODUCTION
  2. MODULES UCS
  3. ACCESSORIES UCS
  4. MODULES OF PROTECTION UCS
  5. THE ERECTING TOOL
  6. METAL STRUCTURES
  7. THE DUST SHIELD
  8. DISTRIBUTIVE BOXINGS
  9. CABINETS




1. INTRODUCTION

The family of skirtings UCS (universal system of connection) is the reliable, rapid and simple before the application system of the cross-connecting connections of conductors.

Special features of contact IDC

Is ensured simplicity of connection, quality and reliability of connection.
  1. Insulating protrusions reliably press conductor at the point of its isolation and provide protection of the region of contact connection from the vibrations and the mechanical actions
  2. The contact edges with the coating for the sake of silver, situated at angle of 45° with respect to the axis of vein, provide the stationary, gas-impermeable contact connection.
  3. As a result the action of thrusts and torsional forces is ensured the reliability of connection.

Technology of the contact connection

The basis of the unit of connection are the contacts, which have contact edges located at angle of 45° with respect to the axis of vein, and insulating protrusions.
The isolation of conductor is cut through with the press-fitting of conductor beside the contact cut with the aid of the erecting tool, and the isolation of conductor is pressed between the formed plastic protrusions. As a result slotting by the contact edges of isolation and constant action of torsional forces are formed two stationary, gas-impermeable contact of surface.
Insulating protrusions reliably fix conductor across both sides relative to contact connection, so that connection cannot be disrupted as a result mechanical actions. Through connection is performed by forming one contact connection on the cable side (a) of skirting and another - on the cross-connection side ([a]') of skirting.


Advantages of the construction of the contact connection of the conductor

The arrangement of contact edges at angle of 45° to the axis of conductor increases contact surface and makes it possible to provide more reliable, more steadfast to the external actions connection.


There are two forms of the skirtings:

Skirting opened UCS-DM is calculated at the point of the protection/the connection of 10 pairs. It ensures the end fitting of conductors without the need for the expenditures of time for the removal of isolation, and also beyond winding or soldering. In the construction of skirting is laid the possibility of fulfilling the measurements of chains before both directions, the break of the connections of chains.

Skirting connecting ([nerazmykaemyy]) UCS- CM is designed for the through connection of 10 pairs. It ensures the end fitting of conductors without the need for the expenditures of time for the removal of isolation, and also beyond winding or soldering.




2. MODULES UCS

№ 233366-000
Designation: UCS-DM-8- W -Sp
Skirting of 8 pairs, opened, white, the numeration of pairs 1-8
Quantity in the box: 10


№ 407646-000
Designation: UCS-CM-8- G -Sp
Skirting of 8 pairs, [nerazmykaemyy], gray, the numeration of pairs 1-8
Quantity in the box: 10


№ 959252-000
Designation: UCS-DM- W -Sp
Skirting of 10 pairs, opened, white, the numeration of pairs 1-0
Quantity in the box: 10

UCS-DM-09- W -Sp
Skirting of 10 pairs, opened, white, the numeration of pairs 0-9




№ 755476-000
Designation: UCS-CM- G -Sp
Skirting of 10 pairs, [nerazmykaemyy], gray, the numeration of pairs 1-0
Quantity in the box: 10

UCS-CM-09- G -Sp
Skirting of 10 pairs, [nerazmykaemyy], gray, the numeration of pairs 0-9



Price see before the division the price list “communication equipment



3. ACCESSORIES UCS

Plugs and the marking caps

Designation: Description Quantity in the box:
958814-000 UCS-BP- W Opening plug down 1 pair, white 100
867612-000 UCS- BP -Bl Opening plug down 1 pair, black 100
889198-000 UCS-BP- R Opening plug down 1 pair, red 100


Designation: Description Quantity in the box:
163650-000 UCS-DP- R Marking [kolp].[na] 1 pair, red 100
841044-000 UCS-DP-BL Marking [kolp].[na] 1 pair, black 100
864392-000 UCS-DP- W Marking [kolp].[na] 1 pair, white 100


Designation: Description Quantity in the box:
953188-000 UCS-BS Opening plug down 10 pairs, white
400





Marking framework

№ 001658-000
Designation: UCS-HLH
Marking hinged framework, gray
Quantity in the box: 40


№ 472114-000
Designation: UCS-MLH
Marking modular framework, gray
Quantity in the box: 16




Measuring cords

the 4- wire measuring cords

Designation: Description
247604-000 UCS-TC- T -2-P/b Measuring cord, 2 m, yellow
308120-000 UCS-TC- T -5-P/b Measuring cord, 5 m, yellow



the 2- wire control cords

Designation: Description
851058-000 UCS-TC- M -2-P/b Control cord, 2 m, yellow
225942-000 UCS-TC- M -5-P/b Control cord, 5 m, yellow

Price see before the division the price list “communication equipment



4. MODULES OF PROTECTION UCS

Surge protection

№ Of c70913-000
Designation: UCS-PR-5GT-230- C
the 5- point module of protection down 1 pair (protection on the current and the voltage) 230 [v]
Standard container: the packet, into which enter 10 modules of the protection + 1 tire of the grounding
Quantity in the box: 100




№ 418338-000
Designation: UCS-OM-3
The store of surge protection, 10 pairs, gray, is supplied without the dischargers
Quantity in the box: 10


№ 312566-000
Designation: MN -ELE-3.50.43
Discharger down 250 [v], fail-safe (with the heat shielding)
Quantity in the box: 100

№ 039272-000
Designation: MN -ELE-3.50.27
Discharger down 230 [v], fail-safe (with the heat shielding)
Quantity in the box: 100


Price see before the division the price list “communication equipment



5. THE ERECTING TOOL

№ 449526-000
Designation: UCS-IT
The erecting tool





Price see before the division the price list “communication equipment



6. METAL STRUCTURES

Assembly yokes

№ 449054-000
Designation: UCS-MF-30-11
Assembly yoke, 30 mm depth, 11 positions


№ 422860-000
Designation: UCS-MF-30-10
Assembly yoke, 30 mm depth, 10 positions


№ 375796-000
Designation: UCS-MF-50-33
Assembly yoke, 50 mm depth, 33 positions






7. THE DUST SHIELD

№ 728190-000
Designation: UCS-DC-100
Dust shield down 100 pairs






8. DISTRIBUTIVE BOXINGS

№ Of d36549-000
Designation: UCS-BET1-30- THE I -Wm
Box is delivered together with the yoke down 3 skirtings, the depth of 11 mm and with the grounding. Sizes: 159 X of 144 X of 79 mm


№ Of f01431-000
Designation: UCS-BET1-50- THE I -Wm
Box is delivered together with the yoke down 5 skirtings, the depth of 11 mm, with the grounding and with the rings for the computation of cords. Sizes: 210 X of 160 X of 90 mm


№ Of f53466-000
Designation: UCS-BET1-100- THE I -Wm
Box is delivered together with the yoke down 10 skirtings, the depth of 30 mm, with the grounding and with the rings for the computation of cords. Sizes: 320 X of 210 X of 120 mm


№ Of f05038-000
Designation: UCS-BET2-200- O
Cross-connecting boxing, with capacity to 20 skirtings. Boxing is delivered with two already established by yokes, by height 50 mm. are applied also rings for the computation of cords. Sizes: 460 X of 340 X of 125 mm


№ Of f55090-000
Designation: UCS-BET2-400- O
Cross-connecting boxing, with capacity to 40 skirtings. Boxing is delivered with four already established by yokes, by height 50 mm. are applied also rings for the computation of cords. Sizes: 460 X of 630 X of 125 mm


№ Of e42822-000
Designation: UCS-BET2-600- O
Cross-connecting boxing, with capacity to 60 skirtings. Boxing is delivered with two already established yokes. Are applied also rings for the computation of cords. Sizes: 460 X of 785 X of 125 mm


№ 192401-000
Designation: MDG-EP-IDTB-KEY10
Key from the locks for the 600- paired boxings. Minimum volume of the order: 10 pcs



Price see before the division the price list “communication equipment



9. CABINETS

№ 940068-000
Designation: UCS-CB-1200- K
Cabinet down 1200 pairs. Internal metal structures and grounding are included. It is supplied without the assembly yokes. Material: polycarbonate with the fiberglass.


№ 400532-000
Designation: UCS-CB-2400- K
Cabinet down 2400 pairs. Internal metal structures and grounding are included. It is supplied without the assembly yokes. Material: polycarbonate with the fiberglass.


Upward
 © [NTTS] the energy
 Communication equipment:
 tel.: (495) 231-22-33, 223-86-83
 e -mail: telecom@synergyexpress.org


design:
STC-ENERGY.ORG
© [NTTS] the energy 
Electronic components: 
tel.: (495) 223-86-83, 231-22-33 
e -mail: complect@synergyexpress.org 

Home Sitemap Contact us

best website of 2009 and 2010. Voted by us:
automobiles.money4car.co.uk , used cars reviews , Best reviews blog , BLC4u meinungen , www.nice-car.co.uk , life insurance