Down the main thing Rambler's Of top100
Catalog of imported communication equipment
Price list the electronic components

on the company
our coordinates
we on the exhibitions
we before the press
our partners
the order of the equipment



the equipment Of tyco
  article for the cable
  - without the pressure
  - under the pressure
  - the inosculation
  cross-connecting equip.
  - the cross-connecting equipment
  fiber optics
  - clutch FOSC
  - crosscountry races, boxings, the cabinets
  - the accessories
  - the tool
the price list Of tyco
the certificates
[otech]. the equipment
the price list



the equipment Of lucent
the price list Of lucent



the equipment
the price list



the equipment
the price list



the equipment
the price list



the equipment
the price list



the Internet- store
to [skachat] the price list


Search:
Rambler's Of top100

THE CATALOG OF EQUIPMENT” TYCO ELECTRONICS RAYCHEM”
Articles for the cable with the copper veins

Clutches and accessories for the cable without the excess pressure:
Heat-shrinkable connecting/splitting clutch (XAGA 500)
Mechanical clutches (T2C, T2C CAP, Gelsnap)
Distributers (VCKT)
Heat-shrinkable repair sleeves (CWST, SLVU)
Heat-shrinkable tubings (ATUM, MWTM, XCSM)
Tip is cap (L -CAPs)

Heat-shrinkable clutch XAGA-500 Heat-shrinkable clutch XAGA-500
The heat-shrinkable connecting/splitting clutch [KHA]GA 500 is intended for using the cables: suspension, laid directly before ground or before the canalization, without the filling and with the vaseline filling, with the polyethylene, lead, steel or aluminum sheath.
Mechanical clutch T2C Mechanical clutch T2C
It is intended for the use with the cables without the excess air pressure - suspension, laid before ground and before the canalization, with the hydrophobic filler and without it. Easily it is revealed and is hermetically sealed. It does not require additional tools for the installation. To 6 applied cables.
Mechanical clutch T2C CAP Mechanical clutch T2C CAP
It is suitable for all types of the cables, which are hung up, lay before the conduit run or directly beside ground. The flexible system of the branching off of the cable: each port ensures hermetic sealing one or several cables. The construction of clutch ensures high resistance to mechanical actions.
Mechanical clutch Of gelsnap Mechanical clutch Of gelsnap
Coupling for the telephone cables Of gelsnap prevents the penetration of moisture, which is reached because of the use of a stagnant gel, which is found under the constant pressure. It can be used due to the most diverse environmental conditions. Different configurations of clutch are possible (blind, passage and splitting).
Distributers VCKT Distributers VCKT
The composition heat-shrinkable clutch VCKT is used as distributive for the cables before the mines of exchanges. Clutch can distribute to 20 cables of crosscountry race. It can be used with any types of cables. There is a possibility of using different number of introductions. The period of storage of clutch is not limited.
Heat-shrinkable repair sleeves CWST Heat-shrinkable repair sleeves CWST
They are suitable for all types of the cables, which lay directly beside ground, conduit run or are hung up. It is intended for the application with the cables with the polyethylene and metal shell, without the filling or with the vaseline filling. The wide range of sizes is calculated at the point of the cables by diameter from 8 to 200 mm.
Heat-shrinkable repair sleeves SLVU Heat-shrinkable repair sleeves SLVU
They are intended for repair and installation of the clutches of MPS. They are capable of maintaining the very high stretching efforts, impacts, pressing, twisting and bends of cable, the wide range of temperature and other external actions. They are established beyond all types of the cable: suspension, laid before ground either before the canalization, without the filling or with the hydrophobic filler, with the polyethylene and metal shell.
Heat-shrinkable tubings ATUM Heat-shrinkable tubings ATUM
The semiflexible heat-shrinkable tubing is developed for guaranteeing the protection from the environmental effect and [germetezatsii] of a whole series of the elements, including of joints (connectors), places of the offshoot of cables, connection of electrical wires. High elasticity makes it possible to hermetically seal strongly [povrezhdennye] cable sheathings.
Heat-shrinkable tubings MWTM Heat-shrinkable tubings MWTM
Heat-shrinkable tubing with the wall of average thickness. It is prepared based on high-quality cross- connected polyolefin. Tube can be supplied without the coating (for the use as the insulator) or with the thermo-fusible pasting coating, which ensures hermetic sealing and protection from mechanical damages, and also with the anticorrosive and sealing coat.
Heat-shrinkable tubings XCSM Heat-shrinkable tubings XCSM
Thick-walled heat-shrinkable tubing. The high coefficient of the shrinkage of tube XCSM makes it possible to use it on the cables with different diameters of shell. It is used on the cables, which lay beside ground or are hung up. Is intended for the use, where it is required maximum reliability (underwater or underground cable laying).
Tip- cap L -CAPs Tip- cap L -CAPs
Heat-shrinkable end caps for the dry or with the cable filler, which are not contained under the excess pressure. Let us use for the cables with the polyethylene and metal shells. It protects from the entry of water inward and thus the longest possible storage of cable without the risk of the penetration of moisture.


Upward
 © [NTTS] the energy
 Communication equipment:
 tel.: (495) 231-22-33, 223-86-83
 e -mail: telecom@synergyexpress.org


design:
STC-ENERGY.ORG
© [NTTS] the energy 
Electronic components: 
tel.: (495) 223-86-83, 231-22-33 
e -mail: complect@synergyexpress.org 


Warning: include(../../../footer.php) [
function.include]: failed to open stream: No such file or directory in /home/synergye/public_html/katalog/tyco/01/BKP_CLND_II/001.php on line 261

Warning: include(../../../footer.php) [function.include]: failed to open stream: No such file or directory in /home/synergye/public_html/katalog/tyco/01/BKP_CLND_II/001.php on line 261

Warning: include() [function.include]: Failed opening '../../../footer.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/synergye/public_html/katalog/tyco/01/BKP_CLND_II/001.php on line 261