CATALOG OF EQUIPMENT” THE MONITORING AND MEASURING EQUIPMENT
Instruments for the optical transmission systems: Optical reflectometer [OR]-2-2; Source of optical radiation OT -2-5/[Ii]; Gauge of optical power OT -2-5/[Im]; Optical tester OT -2-6 (with the built-in source and the gauge of optical radiation);
Optical intercom PU -2; Optical locator- reflectometer [VL]-5 Mobile measuring platform [MTR] 9000 |
[VL]-5 the optical locator- reflectometer Producer: Privately held company “the institute information texnologies "
Optical locator- reflectometer [VL]-5 is intended for attenuation measuring before the optical fibers and their connections, the length of optical fiber and distance to any section of it.
Field of application: building, installation, operation and repair work on [VOLS]. Instrument can work both before the field and laboratory conditions.
Before the regime of locator the instrument automatically determines distance to the heterogeneities or damages of optical cable, measures the losses and the reflection coefficient before these heterogeneities.
|
![[VL]-5 the optical locator- reflectometer](010401.jpg) |
The results of measurements are mapped into symbolic view of the built-in graphic display, and the obtained reflectogram automatically remain before the energy-independent memory of instrument and can be considered subsequently in Personal Computer before the size Of bellcore.
 Before the regime of locator the operator can correct the values of the refractive index of the core of optical fiber, and also change the form of the information, mapped onto display.
Under control Personal Computer the instrument fulfills the functions of reflectometer. Software makes it possible to obtain beyond the screen Personal Computer the complete reflectogram of the measured line and to determine all necessary characteristics [VOLS].
Instrument [VL]-5 ensures:
- the rapid and precise analysis of the parameters of heterogeneities before the line;
- the self-alignment of the parameters of the measurement for achievement of maximum accuracy;
- the possibility of the successive indication of all heterogeneities before the line in accordance with the established threshold values;
- storage of the results of measurements (128 reflectogram);
- work Personal Computer before the regime of valuable reflectometer.
Technical characteristics:
Wavelength, nm Maximum range of distances, km Dynamic range ([OSSH]=1), dB Dead zone on reflection, m Dead zone on damping, m
Error of measurement of the distance: - before the regime of the locator - before the regime of the reflectometer
Interval of discreteness, m Installation of refractive index
Criteria of the determination of the position of the damage: - Fresnel reflection, dB - damping before heterogeneities, dB - the end of fiber, dB
Maximum number alternately the identified heterogeneities Time of the measurement Operating time from the built-in storage batteries Nourishment Overall sizes, mm Mass, the kgf
|
1550±20 180 28 20 40
±30 ± (1+[interval] of [diskretizatsii]+5[Ch]10-5[Ch]L)
4.8 1.0000… 1.9999
From -64 to -43 depending on the distance >2 >5
32
not more than 3 minutes not less than 3 hours the storage batteries of 4x[AA]/~220[V] 226x108x35 not more than 1.0
|
Price see before the division the price list
|
 |